Tadbir company Tadbir company Tadbir company

POWER ANALYZER AC

brand : ACREL COMPANY

PZ Series power analyzer specializes in measuring the data of all kinds of electric networks, such as the currents, the voltages, the powers, the energies etc... It can be used for local display, or it is connected with the control equipment in measuring and controlling system. They comply EN 61326:2006 and EN 61010-1:2001.They are a kind of programmable analyzer. With the 4 key on the front, we can set parameters, such as CT/VT ratio, baudrate etc... They have many auxiliary options, RS-485 (Modbus-RTU), analog output, D/DO and alarm, multi tariffs energies etc.

They are a kind of analyzer with excellent cost performance, They are widely being used in different kinds of control system, SCADA system and power management system.
ترجمه فارسی - پاور آنالایزر شبکه برق AC




Row Product code Product name Technical information description
1 PZ72-E POWER ANALYZER SINGLE PHASE
  • input:1ch 0-450Vac 0-5Aac programmabel
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 72x72mm LED
2 PZ72L-E POWER ANALYZER SINGLE PHASE
  • input:1ch 0-450Vac 0-5Aac programmabel
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 72x72mm LCD
3 PZ80-E POWER ANALYZER SINGLE PHASE
  • input:1ch 0-450Vac 0-5Aac programmabel
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 80x80mm LED
4 PZ80L-E POWER ANALYZER SINGLE PHASE
  • input:1ch 0-450Vac 0-5Aac programmabel
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 80x80mm LCD
5 PZ80-E3 POWER ANALYZER 3 PHASE
  • input:3ch 0-450Vac 0-5Aac programmable
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 80x80mm LED
6 PZ80L-E3 POWER ANALYZER 3 PHASE
  • input:3ch 0-450Vac 0-5Aac programmable
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 80x80mm LCD
7 PZ96-E3 POWER ANALYZER 3 PHASE
  • input:3ch 0-450Vac 0-5Aac programmable
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 96x96mm LED
RS485+multi tariff+maximum demand
8 PZ96L-E3 POWER ANALYZER 3 PHASE
  • input:3ch 0-450Vac 0-5Aac programmable
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 96x96mm LCD
RS485+multi tariff+maximum demand
9 PZ42-E3 POWER ANALYZER 3 PHASE
  • input:3ch 0-450Vac 0-5Aac programmable
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 120x120mm LED

RS485+multi tariff+maximum demand

10 PZ42L-E3 POWER ANALYZER 3 PHASE
  • input:3ch 0-450Vac 0-5Aac programmable
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 120x120mm LCD

RS485+multi tariff+maximum demand

11 PZ96L-EH HARMONIC POWER ANALYZER
  • input:3ch 0-450Vac 0-5Aac programmable
  • 1ch 4-20ma
  • 2ch pulse
  • 2digital input+2digital output+RS485
  • power:85-270Vac/dc
  • 96x96mm LCD

RS485+multi tariff+maximum demand+EVENT RECORDER+Profibus-DP


  • PZ72-E PZ72L-E PZ80-E PZ80L-E
  • U, I, F,P, Q, S, PF,kWh, kvarh,kvAh
  • RS485 + 2DI + 2DO
  • RS485 + 2DI + 2 pulse outputs
  • RS485 + 1 analog outputs + 2 pulse outputs


  • PZ72-E3
  • VL1,VL2,VL3
  • VL12,VL23,VL31
  • AL1,AL2,AL3,F,
  • P,P1,P2,P3,
  • Q,Q1,Q2,Q3,S,S1,
  • S2,S3,PF,PF1,PF2,
  • PF,MD kW,
  • +/-kWh,+/-kvarh
  • RS485 + 1 pulse output


  • PZ80-E3
  • RS485 + 2DI + 2DO
  • RS485 + 4DI + 1 pulse output


  • PZ80L-E3 LCD
  • RS485 + 1 analog outputs + 2 pulse outputs


  • PZ96-E3
  • RS485 + 2DI + 2DO
  • RS485 + 4DI + 2DO
  • RS485 + 2 analog outputs + 2 pulse outputs


  • PZ96L-E3 LCD
  • RS485 + 2DI + 2DO
  • RS485 + 4DI + 2DO
  • RS485 + 4DI + 1 pulse output


  • PZ42-E3C
  • RS485 + 8DI + 4DO
  • RS485 + 8DI + 2 pulse output
  • RS485 + 2 analog outputs + 2 pulse outputs


  • PZ42L-E3 LCD
  • RS485 + 8DI + 2DO
  • RS485 + 2 analog outputs + 2 pulse outputs


اطلاعات بیشتر
Technical parameter

  • Input: Network 1P2W.3P3W.3P4W
  • Frequency 45Hz ~ 65Hz
  • Voltage: AC 100V, 400V (programmable)
  • Overload: 480V (continuous); 800V during 30s
  • Consumption: < 0.2VA
  • Current: Rating: AC 1A, 5A (programmable)
  • Overload: 6A (continuous); 50A during 30s
  • Consumption: < 0.2VA
  • Thermal drift <200ppm
  • CT/VT ratio CT and VT ratio can be programmable
  • Options
  • Analog output: (M) DC 0 ~ 20mA, 4 ~ 20mA (Load capacity: < 600Ω)
  • Digital output: (DO) NO-NC contact relay (to control the status of switches
  • Contact capacity: AC 250V/3A, DC 30V/3A
  • Digital input: (DI) Dry contact Input (with 5V power) (to display the switches' status)
  • Alarm output: (J) Alarm of over voltage, under voltage and over current
  • The hysteresis and the delay can be programmable
  • Communication: RS485 (Modbus-RTU protocol)
  • Pulse output: pulse outputs (open-collector),>
  • Pulse constant: 10000, 40000, 160000 imp/kWh
  • Multi tariff: kWh (/F) up ot 4 tariffs and 8 time zones in one day
  • Display: LED, LCD>
  • Precision: 0.5 (F: 0.05Hz; kVar: 1)
  • Power supply: AC/DC 85 ~ 270V; Consumption < 4VA
  • Isolation: 2kVAC/min (voltage input / power; between current inputs)1.5kVAC/min (outputs / power)
  • Isolation resistor input / housing and output / housing >100MΩ
  • Environment
  • Work T: -20C ~ +55C
  • Storage T: -20C ~ +70C
  • Relative humidity: 5% ~ 95% (no condensation)
  • Altitude: < 2500m